DocumentCode
1663610
Title
End-winding effect on shaft voltage in AC generators
Author
Adabi, Jafar ; Zare, Firuz ; Ghosh, Arindam
Author_Institution
Queensland Univ. of Technol., Brisbane, QLD, Australia
fYear
2009
Firstpage
1
Lastpage
10
Abstract
This paper presents effects of end-winding on shaft voltage in AC generators. A variety of design parameters have been considered to calculate the parasitic capacitive couplings in the machine structure with Finite Elements simulations and mathematical calculations. End-winding capacitances have also been calculated to have a precise estimation of shaft voltage and its relationship with design parameters in AC generators.
Keywords
AC generators; finite element analysis; power convertors; windings; AC generators; end-winding effect; finite elements simulations; parasitic capacitive couplings; shaft voltage; AC generators; Frequency; Induction motors; Parasitic capacitance; Power system modeling; Pulse width modulation; Pulse width modulation inverters; Shafts; Stators; Voltage; AC generator; Common mode; End-winding; FEM; Shaft voltage; design parameters;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Applications, 2009. EPE '09. 13th European Conference on
Conference_Location
Barcelona
Print_ISBN
978-1-4244-4432-8
Electronic_ISBN
978-90-75815-13-9
Type
conf
Filename
5278851
Link To Document