Abstract :
The DECADE Quad (DQ) is a Defense Threat Reduction Agency´s radiation effects simulator consisting of four individual DECADE Modules (DMs). When operated as a large area Bremsstrahlung source, each of the DMs utilize separate plasma opening switches (POSs) and e-beam loads. A monolithic POS for DQ is being developed for small area Bremsstrahlung source applications requiring a single e-beam diode. Power flow from the four DMs will be converged upstream of the monolithic POS which will drive a nominal 0.2 /spl Omega/, small area Bremsstrahlung source. The baseline approach for the development of a monolithic switch for DQ is a POS currently being tested on ACE 4. The applicability of ACE 4 as a test bed is based on a conduction current time(I/sub c/*T/sub c/) scaling argument applied to the conduction phase. The key concept for I/sub c/*T/sub c/ scaling, the preservation of the opening phase initial conditions, has both experiment and theoretical support. The DQ prototype coaxial POS uses a 9 cm radius cathode, a 3 cm A-K gap, and has a nominal 20 cm length. A set of 15 Teflon(R) substrate flashboards supply the necessary POS plasma, injected through a 60% transparent anode mesh. Issues being addressed in this development besides I/sub c/*T/sub c/ scaling include an understanding of current losses due to ion currents in the POS region and PQS-to-load coupling issues related to POS opening and plasma transport into the load region. In this paper, the authors report on the characterization of several POS-to-load coupling geometries on ACE 4.
Keywords :
anodes; bremsstrahlung; electron beams; plasma switches; pulse generators; pulsed power supplies; pulsed power switches; switchgear testing; 0.2 ohm; 20 cm; 3 cm; 9 cm; ACE 4; DECADE Modules; DECADE Quad monolithic POS development; Defense Threat Reduction Agency; POS-to-load coupling geometries; Teflon substrate flashboards; conduction current time; e-beam loads; pulsed power plasma opening switch; radiation effects simulator; small area Bremsstrahlung source; transparent anode mesh; Coaxial components; Diodes; Load flow; Plasma applications; Plasma simulation; Plasma sources; Prototypes; Radiation effects; Switches; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 1999. Digest of Technical Papers. 12th IEEE International
Conference_Location :
Monterey, CA, USA
Print_ISBN :
0-7803-5498-2
Type :
conf
DOI :
10.1109/PPC.1999.825449
Filename :
825449
Link To Document :
بازگشت