Title :
Thermal loss measurements of high frequency planar transformers
Author :
Buettner, A. ; Nysveen, A. ; Hernes, M.
Author_Institution :
Norwegian Univ. of Sci. & Technol., Trondheim, Norway
Abstract :
This article presents the capability of using a tailor made thermal loss measurement tool to evaluate different winding designs for resonant switch mode transformers in power supplies with frequencies above 500 kHz. The measurement tool can meter losses, directly displaying them in only a few minutes (depending on the heat capacity of the material under test). Different winding designs for a planar transformer have been tested. A revolved parallel winding lay-out has performed best in a short-circuit loss test.
Keywords :
loss measurement; power transformer testing; switched mode power supplies; transformer windings; high frequency planar transformers; parallel winding lay-out; resonant switch mode transformers; short-circuit loss test; thermal loss measurements; Circuit testing; Costs; Frequency conversion; Frequency measurement; Interleaved codes; Loss measurement; Resonance; Switched-mode power supply; Switches; Transformers; High frequency power converter; Measurement; Transformer out of official keywords list;
Conference_Titel :
Power Electronics and Applications, 2009. EPE '09. 13th European Conference on
Conference_Location :
Barcelona
Print_ISBN :
978-1-4244-4432-8
Electronic_ISBN :
978-90-75815-13-9