Title :
AC current measurements via digital processing of Rogowski coils signal
Author :
Antona, G. D´ ; Carminati, E. ; Lazzaroni, M. ; Ottoboni, R. ; Svelto, C.
Author_Institution :
Dipt. di Elettrotecnica, Politecnico di Milano, Italy
fDate :
6/24/1905 12:00:00 AM
Abstract :
The main advantages of Rogowski coils are the high degree of galvanic insulation and low cost compared to shunts and current transformer measuring systems. Its typical application is in the field of high-amplitude and/or high frequency currents. The integration of the EMF induced at the end conductors of the coil is classically obtained by an analog integrator. We propose an original integration process, based on a simple digital signal processing, allowing for better accuracy in the integration procedure and higher stability of the output signal. In addition, the use of digital integration extends the use of Rogowski coils also to low-amplitude and low-frequency current measurements.
Keywords :
coils; crosstalk; current transformers; electric current measurement; measurement errors; signal sampling; AC current measurements; Rogowski coils; absolute measurement errors; crosstalk test; current transducer; digital signal processing; high galvanic insulation; higher stability; induced EMF; induction coil; integration process; low cost; low-amplitude current measurements; low-frequency current measurements; mutual inductance; Coils; Conductors; Costs; Current measurement; Current transformers; Digital signal processing; Frequency; Galvanizing; Power transformer insulation; Signal processing;
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2002. IMTC/2002. Proceedings of the 19th IEEE
Print_ISBN :
0-7803-7218-2
DOI :
10.1109/IMTC.2002.1006926