DocumentCode :
1666054
Title :
Atlas transmission line breakdown analysis
Author :
Nielsen, K.E. ; Davis, H.A. ; Ballard, E.O. ; Elizondo, J.M. ; Gribble, R.F. ; McCuistian, B.T. ; Parsons, W.M.
Author_Institution :
Los Alamos Nat. Lab., NM, USA
Volume :
1
fYear :
1999
Firstpage :
381
Abstract :
The Atlas facility will use 24 radially converging, vertically oriented and tapered, oil insulated, triplate transmission lines between the Marx generators and the central load region. Among the requirements of the transmission lines are low inductance and high reliability. The inter-conductor gap is nominally 2 cm and the lines taper from a height of 1.75 m at the Marx end to 0.32 m at the output end. The aluminum conductors, held together by 20 insulating spacers, are assembled and inserted as a unit into radial oil-filled steel tanks. The negative, high-voltage, center conductor is 2.54-cm thick and the outer ground conductors are 1.59-cm thick. All 24 triplate transmission lines connect to a transition section at near 1 m radius that couples the transmission lines to a disk/conical solid-dielectric-insulated power flow channel transmission line terminating at the load. Peak operating voltage on the lines can be as high as 240 kV with an effective stress time of 0.8 /spl mu/s. Testing of small sections of the total area have been completed and the test results are analyzed to show that the probability of failure at these voltage levels is less than 1 in 1000 system shots.
Keywords :
conductors (electric); electric breakdown; failure analysis; insulating oils; power transmission; probability; pulse generators; pulsed power supplies; 1 m; 1.59 cm; 1.75 m; 2 cm; 2.54 cm; 240 kV; 8 mus; Atlas transmission line breakdown analysis; Marx generators; aluminum conductors; center conductor; central load region; disk/conical transmission line; failure probability; high reliability; high-voltage conductor; insulating spacers; inter-conductor gap; low inductance; negative conductor; outer ground conductor; peak operating voltage; radial oil-filled steel tanks; radially converging triplate transmission lines; solid-dielectric-insulated power flow channel transmission line; tapered oil insulated triplate transmission lines; triplate transmission lines; vertically oriented triplate transmission lines; Aluminum; Conductors; Electric breakdown; Inductance; Oil insulation; Petroleum; Power transmission lines; System testing; Transmission lines; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 1999. Digest of Technical Papers. 12th IEEE International
Conference_Location :
Monterey, CA, USA
Print_ISBN :
0-7803-5498-2
Type :
conf
DOI :
10.1109/PPC.1999.825490
Filename :
825490