Abstract :
An analysis was performed to determine whether an increased shock hazard occurs with 2400-V continuous-miner trailing cables, as compared with those used with existing low and medium-voltage systems. (It should be noted that the Code of Federal Regulations defines low-voltage, medium-voltage, and high-voltage for mine power systems as 0 - 660 V, 661 - 1000 V, and greater than 1000 V, respectively). The study assumed that Mine Safety and Health Administration´s Proposed Rule for High-Voltage Continuous Mining Machines was implemented with the exception of the special cable- handling requirements. Two major differences between the high-voltage proposed rule and existing low and medium-voltage regulations that are relevant to this study deal with ground-fault protection and include: (1) The maximum ground-fault current of the 2400-V system must be limited to 0.5 A, while the low and medium- voltage systems typically use a limit of 15 A, and (2) The maximum ground-fault pickup of the 2400-V system must be set at 0.125 A with a maximum time delay of 0.05 s; whereas, low and medium-voltage systems require an instantaneous pickup set at, or below, 40% of the maximum ground-fault current (6 A for 15-A systems). Results of the study show that the 2400-V trailing cable, in conjunction with the strict ground-fault protection requirements and enhanced cable construction, provide a higher level of safety compared with the trailing cables used on low and medium-voltage continuous miners.
Keywords :
electrical safety; hazards; mining industry; power cable testing; coal mining; continuous mining machines; current 0.125 A; current 0.5 A; current 15 A; ground-fault protection; safety analysis; shock hazards; trailing cables; voltage 2400 V; Delay effects; Electric shock; Hazards; Health and safety; Low voltage; Medium voltage; Performance analysis; Power cables; Power system analysis computing; Protection;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 2007. 42nd IAS Annual Meeting. Conference Record of the 2007 IEEE
Conference_Location :
New Orleans, LA
ISSN :
0197-2618
Print_ISBN :
978-1-4244-1259-4
Electronic_ISBN :
0197-2618
Type :
conf
DOI :
10.1109/07IAS.2007.214
Filename :
4347963
Link To Document :
بازگشت