Abstract
High-frequency analog designs need to make trade-off between performance and sufficient ESD protection due to unwanted parasitics which slow down the circuit. An HBM failure diagnosis on a chip without complete ESD protection achieves silicon correlation with a full-chip dynamic ESD simulation. An innovative critical path tracing technique for diagnosis assistance is also described.
Keywords
analogue circuits; circuit reliability; electrostatic discharge; failure analysis; ESD protection; HBM failure diagnosis; full-chip dynamic ESD simulation; high-frequency analog design; human body model; innovative critical path tracing technique; silicon correlation; Clamps; Discharges (electric); Electrostatic discharges; Hidden Markov models; Junctions; Power system dynamics; Transistors;