• DocumentCode
    1667352
  • Title

    Microassembly combining pick-and-place and water mist

  • Author

    Chang, Bo ; Jääskelainen, Mirva ; Zhou, Quan

  • Author_Institution
    Dept. of Autom. & Syst. Technol., Aalto Univ., Aalto, Finland
  • fYear
    2010
  • Firstpage
    333
  • Lastpage
    337
  • Abstract
    This paper reports a novel and versatile hybrid microassembly technique that applies water mist on the surface of microparts to assist alignment of microchips. This technique combines the traditional robotic pick-and-place technique and self-assembly technique. Two different approaches are studied: 1) mist-last where a 200μm × 200μm × 70μm SU-8 chip is placed roughly on another chip of the same size using a microgripper and then water mist is delivered to achieve self-alignment; 2) mist-first where water mist is delivered before the releasing of a chip near the target. The second approach is further studied to examine the maximum tolerance of placement error and placement of chips on hydrophilic/hydrophobic patterns. The experimental results indicate the proposed technique is reliable and versatile for stacking and assembling microchips. a 200μm × 200μm × 70μm SU-8 chip was assembled on the top of another SU-8 chip of the same dimensions, where the success rate can reach 75% with bias as high as 180μm. Microparts of size 200μm × 200μm × 70μm can be successfully assembled on hydrophilic/hydrophobic patterns.
  • Keywords
    grippers; microassembling; microassembly technique; microgripper; pick-and-place; robotic pick-and-place technique; self-assembly technique; water mist; Grippers; HEMTs; Jacobian matrices; MODFETs; Robots; Silicon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Micro-NanoMechatronics and Human Science (MHS), 2010 International Symposium on
  • Conference_Location
    Nagoya
  • Print_ISBN
    978-1-4244-7995-5
  • Type

    conf

  • DOI
    10.1109/MHS.2010.5669526
  • Filename
    5669526