DocumentCode
1668673
Title
Temperature Estimation in Inverter Fed Machines Using High Frequency Carrier Signal Injection
Author
Briz, Fernando ; Degner, Michael W. ; Guerrero, Juan M. ; Diez, Alberto B.
Author_Institution
Univ. of Oviedo, Gijon
fYear
2007
Firstpage
2030
Lastpage
2037
Abstract
Temperature monitoring using the injection of a high frequency, carrier signal voltage is proposed in this paper. The carrier signal voltage is used to estimate the transient impedance of the system, which is a function of the stator transient resistance, and therefore, the windings´ temperature. The variation of the stator transient impedance´s phase angle is used to track the temperature of the stator windings. The method can be implemented in standard, inverter-fed drives with no additional hardware, minimal computational requirements, and practically no interference with the regular operation of the drive.
Keywords
asynchronous machines; electric drives; electric impedance measurement; parameter estimation; stators; carrier signal injection; inverter fed machine drives; stator transient impedance; stator transient resistance; temperature estimation; temperature monitoring; Frequency estimation; Hardware; Impedance; Inverters; Signal processing; Stator windings; Temperature sensors; Thermal resistance; Torque; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 2007. 42nd IAS Annual Meeting. Conference Record of the 2007 IEEE
Conference_Location
New Orleans, LA
ISSN
0197-2618
Print_ISBN
978-1-4244-1259-4
Electronic_ISBN
0197-2618
Type
conf
DOI
10.1109/07IAS.2007.307
Filename
4348056
Link To Document