Title
Artery skeleton extraction based on consistent curvature labeling
Author
Haris, K. ; Maglaveras, Nicos ; Efstratiadis, SN ; Gourassas ; Pappas, C. ; Louridas, G.
Author_Institution
Lab. of Med. Inf., Aristotle Univ., Thessaloniki, Greece
fYear
1999
fDate
6/21/1905 12:00:00 AM
Firstpage
269
Lastpage
272
Abstract
A method for detecting and extracting the skeletons of coronary arteries in coronary angiograms is proposed. The grayscale coronary angiograms are regarded as noisy sampling of the underlying continuous surface. After the application of Gaussian filtering to reduce noise, the topographic features of the smoothed image are detected based on first and second order image derivatives which characterize the local differential image structure. Then, the candidate arteries skeleton areas are detected based on the observation that arteries are smooth elongated objects having approximately a Gaussian smoothed semi-elliptical profile. False skeleton areas are eliminated through connected component analysis and the morphological operation of reconstruction. Experimental results on real digitized coronary angiograms are presented
Keywords
angiocardiography; feature extraction; image reconstruction; medical image processing; Gaussian filtering; artery skeleton extraction; connected component analysis; consistent curvature labeling; false skeleton areas; grayscale coronary angiograms; medical diagnostic imaging; morphological operation; noise reduction; noisy sampling; Arteries; Filtering; Gaussian noise; Gray-scale; Image sampling; Labeling; Noise reduction; Skeleton; Surface morphology; Surface topography;
fLanguage
English
Publisher
ieee
Conference_Titel
Computers in Cardiology, 1999
Conference_Location
Hannover
ISSN
0276-6547
Print_ISBN
0-7803-5614-4
Type
conf
DOI
10.1109/CIC.1999.825958