• DocumentCode
    1671405
  • Title

    Three-D localization of the coronary segment and calibration catheter to correct for differential magnification in quantitative coronary angiography

  • Author

    Wunderlich, W. ; Roehrig, B. ; Morguet, A.J. ; Fischer, F. ; Arntz, H.R. ; Agrawal, R. ; Schultheiss, H.P.

  • Author_Institution
    Benjamin Franklin Univ. Hosp., Free Univ., Berlin, Germany
  • fYear
    1999
  • fDate
    6/21/1905 12:00:00 AM
  • Firstpage
    371
  • Lastpage
    374
  • Abstract
    The objective was to quantify the measurement errors of the major coronary segments resulting from nonidentical radiographic magnification of the segment and calibration catheter. The 3D location of 468 coronary segments and of the corresponding coronary catheter tip were assessed using biplane angiography and known projection data. The potential measurement error was then calculated in tabular form by simulating viewing angles over the full range of angiographic projections. Rotation from RAO to LAO results in a mean error changing from -4% to +5% for the RCA and from +5% to -6% for the LAD and LCx arteries. Error diagrams were established from which the potential diameter error for each CASS defined coronary segment in each specific projection may be taken from. In monoplane quantitative coronary angiography, the accuracy of catheter calibration may be improved using error diagrams. The correction should be performed simultaneously with other sources of error
  • Keywords
    blood vessels; calibration; diagnostic radiography; measurement errors; medical image processing; CASS defined coronary segment; angiographic projections; arteries; biplane angiography; calibration catheter; catheter calibration; coronary catheter tip; differential magnification; error diagrams; known projection data; major coronary segments; measurement errors; monoplane quantitative coronary angiography; nonidentical radiographic magnification; potential diameter error; segment catheter; specific projection; tabular form; three dimensional location; three-dimensional localization; viewing angles; Angiography; Arteries; Calibration; Catheters; Computer errors; Error correction; Heart rate; Image segmentation; Radiography; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology, 1999
  • Conference_Location
    Hannover
  • ISSN
    0276-6547
  • Print_ISBN
    0-7803-5614-4
  • Type

    conf

  • DOI
    10.1109/CIC.1999.825984
  • Filename
    825984