DocumentCode :
1673285
Title :
Vascular Orientation Detection and Feature Point Recognition of Coronary Arterial Angiogram Based on Multi-Scale Gabor Filter
Author :
Li, Qin ; Wang, Ting ; Shui, Haomiao ; Hu, Xiaoming ; Liu, Yue ; Wang, Yongtian
Author_Institution :
Dept. of Biomed. Eng., Beijing Inst. of Technol., Beijing
fYear :
2008
Firstpage :
2477
Lastpage :
2480
Abstract :
The article proposed an algorithm for vascular orientation detection based on Gabor filter. The vascular orientation can be detected by extracting the oriented feature points that were helpful to recognize and judge the key points on the coronary artery. The data about the feature points were necessary for three dimensional reconstruction of coronary artery. The algorithm also could reduce the time consumption for a large scale, and be suitable for the other kind of image.
Keywords :
angiocardiography; blood vessels; coronary arterial angiogram; multiscale Gabor filter; vascular orientation detection; Arteries; Biomedical engineering; Computer vision; Data mining; Equations; Feature extraction; Gabor filters; Image reconstruction; Large-scale systems; Skeleton;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on
Conference_Location :
Shanghai
Print_ISBN :
978-1-4244-1747-6
Electronic_ISBN :
978-1-4244-1748-3
Type :
conf
DOI :
10.1109/ICBBE.2008.952
Filename :
4535832
Link To Document :
بازگشت