• DocumentCode
    1676751
  • Title

    Analysis of the assistance characteristics for the plantarflexion torque in elderly adults wearing the powered ankle exoskeleton

  • Author

    Kim, Kyung ; Kim, Jae-Jun ; Kang, Seung-Rok ; Jeong, Gu-Young ; Kwon, Tae-kyu

  • Author_Institution
    Dept. of Biomed. Eng., Chonbuk Nat. Univ., Seoul, South Korea
  • fYear
    2010
  • Firstpage
    576
  • Lastpage
    579
  • Abstract
    Ankle exoskeleton with an artificial pneumatic actuator, which is intended for the assistance and enhancement of muscular activity, was developed. In this study, the effectiveness of the system was investigated during plantarflexion motion of ankle joint. To find an effectiveness of the system, the subjects performed maximal voluntary isokinetic plantarflexion contraction on a Biodex-dynamometer. Plantarfexion torque of the ankle joint is assisted by subject´s soleus muscle that is generated when ankle joint do plantarflexion motion. We used the muscular stiffness signal of a soleus muscle for feed-forward control of ankle-foot orthosis as physiological signal. For measurement of this signal, we made the muscular stiffness force sensor. We compared a muscular stiffness force of a soleus muscle between with feed-forward control and without it and a maximal plantarflexion torque between not wearing a ankle-foot orthosis, without feed-forward control wearing it and with feed-forward control wearing it in each ten elderly adults. The experimental result showed that a muscular stiffness force of a soleus muscle with feed-forward control was reduced and plantarflexion torque of an ankle joint only wearing ankle-foot orthosis was reduced but a plantarflexion torque with feed-forward control was increased. The amount of a increasing with feed-forward control is higher than the amount of a decreasing only wearing it. Therefore, we confirmed the effectiveness of the developed ankle-foot orthosis with feed-forward control.
  • Keywords
    feedforward; force sensors; geriatrics; handicapped aids; orthotics; torque control; Biodex-dynamometer; ankle joint; ankle-foot orthosis; artificial pneumatic actuator; assistance characteristics; elderly adult; feedforward control; muscular activity; muscular stiffness force sensor; muscular stiffness signal; physiological signal; plantarflexion motion; plantarflexion torque; powered ankle exoskeleton; soleus muscle; voluntary isokinetic plantarflexion contraction; Current measurement; Foot; Joints; Muscles; Senior citizens; Torque; Torque measurement; muscular stiffness force feed-forward control; plantarflexion torque; powered ankle exoskeleton;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control Automation and Systems (ICCAS), 2010 International Conference on
  • Conference_Location
    Gyeonggi-do
  • Print_ISBN
    978-1-4244-7453-0
  • Electronic_ISBN
    978-89-93215-02-1
  • Type

    conf

  • Filename
    5669921