Abstract :
An analysis of different 2DOF PI controller tuning methods in [1], [2] showed significant advantages of a noise attenuation oriented predictive disturbance observer based filtered PI control (PDO-FPI) against the traditional two degree of freedom (2DOF) PI control. Analytically, as well as by the numerical performance portrait method it discovered that the potential improvements in the disturbance response are significantly higher than those in the setpoint response. This paper shows that the PDO-FPI does not make use of the whole control potential regarding the analysed first order plants with a possible dead time. The corresponding control structures will be derived by augmenting the well known control loop with a reference model by an additional disturbance observer for an input disturbance. The theoretical analysis will be illustrated by experimental results.
Keywords :
PI control; control system analysis; control system synthesis; feedforward; numerical analysis; observers; 2DOF PI controller; PDO-FPI; control loop; disturbance response; dynamical feedforward control; filtered PI control; first order system; noise attenuation oriented predictive disturbance observer; numerical performance portrait method; reference model; Delays; Feedforward neural networks; Observers; PD control; Pi control; Transient analysis; Tuning;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Power Engineering (EPE), 2014 International Conference and Exposition on
Conference_Location :
Iasi
Type :
conf
DOI :
10.1109/ICEPE.2014.6969872
Filename :
6969872
Link To Document :
بازگشت