Abstract :
A prototype automated diagnosis system for a real-world unit under test (UUT) is presented. The system features a time-optimized test sequence with feedback of correctly diagnosed failures and a reduction of effort for test program development and maintenance. The diagnostic strategy used involves associative and model-based diagnosis. The experimental knowledge is organized as a hierarchical rulebase structure according to diagnoses. To model physical knowledge, a technique using logic programming extended by functions is introduced
Keywords :
automatic test equipment; expert systems; maintenance engineering; associative diagnosis; expert system controlled automatic test system; feedback; hierarchical rulebase structure; logic programming; maintenance; model-based diagnosis; prototype automated diagnosis system; real-world unit under test; test program development; time-optimized test sequence; Automatic control; Automatic testing; Control systems; Diagnostic expert systems; Electronic equipment testing; History; Knowledge based systems; Logic testing; Maintenance; System testing;