DocumentCode
1678164
Title
Thickness quality control and diagnosis system for tinplate rolling mills
Author
Enguita, J.M. ; Fernandez, Yolanda ; Rendueles, J.L.
Author_Institution
Dept. of Electr. Eng., Oviedo Univ., Spain
Volume
2
fYear
2004
Firstpage
919
Abstract
The draw wall ironed (DWI) tinplate market clearly trends to demand a reduction in thickness, which implies stricter tolerance levels as small variations could result in problems in the manufacturing process and therefore customer´s dissatisfaction in a highly competitive market. This paper describes a series of methods to detect thickness defects in DWI tinplate. In addition, these methods provide information to identify the origin of the defects, allowing fast corrections and therefore improving mill performance. In our approach an adapted thickness signal is spatially sampled from the input stages of the mill´s last X-ray gauge.
Keywords
customer satisfaction; plates (structures); production control; quality control; rolling mills; thickness control; draw wall ironed tinplate market; thickness diagnosis system; thickness quality control; thickness reduction; tinplate rolling mill; Coils; Fingers; Manufacturing processes; Milling machines; Production; Quality control; Shape; Steel; Strips; Thickness measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 2004. 39th IAS Annual Meeting. Conference Record of the 2004 IEEE
ISSN
0197-2618
Print_ISBN
0-7803-8486-5
Type
conf
DOI
10.1109/IAS.2004.1348522
Filename
1348522
Link To Document