  • Title

    CAD/CAE modeling of the human exposure to electric field inside a high voltage substation

  • Author

    Munteanu, Calin ; Purcar, Marius ; Bursasiu, Dan ; Merdan, Emil ; Farcas, Vasile

  • Author_Institution
    Dept. of Electrotecnhics & Meas., Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania
  • fYear
    2014
  • fDate
    16-18 Oct. 2014
  • Firstpage
    476
  • Lastpage
    479
  • Abstract
    This paper presents the computer aided design (CAD) and computer aided engineering (CAE) modeling of Cluj-Sud 110 kV high voltage substation in order to examine the influence of substation constructive elements and apparatus (e.g. phase conductors, bypass bus bars, breakers and towers) on the spatial electric field distribution. The substation belongs to FDEE Electrica distributie Transilvania Nord SA. In a first step the detailed three dimensional (3D) CAD models of the substation components are constructed and assembled in the CAD environment SolidWorks. Then the exact 3D coordinates of the terminals are automatically retrieved and the electric field distribution is computed on the 3D CAD model using a CAE software developed. The electric field distribution is represented on horizontal and transversal slices at the 3D CAD model in order to highlight the high intensity field zones and compare them with respect to the actual legislation norms of human exposure.
  • Keywords
    CAD; bioelectric phenomena; biological effects of fields; biomagnetism; busbars; computer aided engineering; conductors (electric); electric fields; electrical engineering computing; high-voltage engineering; medical computing; poles and towers; safety; substations; 3D CAD model horizontal slice; 3D CAD model transversal slice; 3D CAD modeling; CAD environment; CAE modeling; Cluj-Sud high voltage substation; SolidWorks; automatic 3D terminal coordinate retrieval; computer aided design modeling; computer aided engineering modeling; electric field distribution computation; electric field exposure; high intensity field zone; human exposure; legislation norm; spatial electric field distribution; substation apparatus effect; substation breaker; substation bypass bus bar; substation component model; substation constructive element effect; substation phase conductor; substation tower; three dimensional CAD model; voltage 110 kV; Computational modeling; Conductors; Design automation; Electric fields; Solid modeling; Substations; Three-dimensional displays; CAD/CAE modeling; High voltage substation; electromagnetic field; human exposure;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Power Engineering (EPE), 2014 International Conference and Exposition on
  • Conference_Location
    Iasi
  • Type

    conf

  • DOI
    10.1109/ICEPE.2014.6969953
  • Filename
    6969953