• DocumentCode
    1679570
  • Title

    Simulation and design of ultrasonic flow sensor

  • Author

    Zhao, Weiguo ; Shen, Pingping ; Yang, Songying ; Liang, Guowei ; Lin, Kangwei ; Li, Wenjun

  • Author_Institution
    Coll. of Metrol. & Meas. Eng., China Jiliang Univ., Hangzhou, China
  • fYear
    2010
  • Firstpage
    5484
  • Lastpage
    5487
  • Abstract
    In order to solve the pipeline influence on measurement accuracy, the software Fluent was introduced to simulate the flow condition of the ultrasonic sensor. Through the simulation of different kinds of pipeline, the ultrasonic signal was analyzed and compared. The final form of the pipeline was obtained and the ultrasonic sensor was designed. The water experiments proved the design is valid.
  • Keywords
    computational fluid dynamics; flow measurement; flow sensors; flow simulation; pipelines; ultrasonic transducers; flow condition; measurement accuracy; pipeline influence; software Fluent; ultrasonic flow sensor; ultrasonic signal; water experiments; Acoustics; Computational fluid dynamics; Fluid flow measurement; Metrology; Pipelines; Software measurement; Ultrasonic variables measurement; design; sensor; simulation; ultrasonic;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Control and Automation (WCICA), 2010 8th World Congress on
  • Conference_Location
    Jinan
  • Print_ISBN
    978-1-4244-6712-9
  • Type

    conf

  • DOI
    10.1109/WCICA.2010.5554138
  • Filename
    5554138