DocumentCode
167969
Title
Data acquisition system for testing the insulation between the stator laminations of high power electrical machines
Author
Calin, Florin ; Oancea, Constantin Daniel
Author_Institution
Fac. of Electr. Eng., Politeh. Univ. of Bucharest, Bucharest, Romania
fYear
2014
fDate
16-18 Oct. 2014
Firstpage
715
Lastpage
719
Abstract
The paper presents fault detection equipment used for insulation testing between the stator laminations of high power machines. To give more flexibility of a measurement system, a software component must take in consideration. This paper complete previously theoretical model developed. The equipment presented provides the opportunity to test the insulation between the stator laminations of electric machines for a wide power range with a clear diagnosis of the presence of defects in insulation between the stator laminations. The paper focuses on virtual instrument, data acquisition, control, and interface on the acquired signals.
Keywords
data acquisition; electric machines; fault diagnosis; insulation testing; laminations; measurement systems; reliability; stators; virtual instrumentation; data acquisition system; defect diagnosis; fault detection equipment interface; high power electric machine stator lamination; insulation testing; measurement system control; software component; virtual instrument; Data acquisition; Insulation; Lamination; Software; Stator cores; Voltage measurement; distance sensor; electrical machines; insulation; testing; virtual instrumentation;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical and Power Engineering (EPE), 2014 International Conference and Exposition on
Conference_Location
Iasi
Type
conf
DOI
10.1109/ICEPE.2014.6970002
Filename
6970002
Link To Document