    Detection of insulator ageing

  • Author

    Jermendy, L. ; Fogarasi, I.

  • Author_Institution
    Electr. Large Labs. Ltd., Budapest, Hungary
  • fYear
    1999
  • Firstpage
    128
  • Abstract
    Various tests were performed on glass cap insulators under laboratory conditions. Laboratory methods were selected for a systematic insulator diagnosis on porcelain cap and long rod insulators. Electromechanical parameters of the aged insulators may be reduced to half the original value, to far below the required values. The power frequency wet test proved the ageing for other type of insulator strings too. The monitoring of leakage current impulses helps to follow the procedure. The selection of these impulses detects the mechanical defects of the insulators.
  • Keywords
    ageing; electric breakdown; impulse testing; insulator testing; leakage currents; aged insulators; electromechanical parameters; glass cap insulators; insulation breakdown tests; insulator ageing detection; insulator strings; laboratory conditions; leakage current impulses monitoring; long rod insulators; mechanical defects detection; power frequency wet test; Aging; Frequency; Glass; Insulation; Insulator testing; Laboratories; Leakage current; Monitoring; Performance evaluation; Porcelain;
  • fLanguage
    English