• DocumentCode
    1685665
  • Title

    Design of the ultra low power, low area occupied amplifier for recording biomedical signals in the single Hz bandwidth

  • Author

    Kmon, Piotr ; Grybos, Pawel

  • Author_Institution
    AGH Univ. of Sci. & Technol., Krakow, Poland
  • fYear
    2015
  • Firstpage
    314
  • Lastpage
    317
  • Abstract
    We report on design of the amplifier dedicated to recording very low frequency biomedical signals. As the amplifier is used in multichannel integrated circuit dedicated to biomedical signals acquisition its key requirements are very low power consumption and low area occupation. The amplifier is designed in 180 nm CMOS process, occupies 58×55 μm2, and allows to set its bandwidth in the single Hz range. It is supplied from 1.8 V and is characterized by sub μW power consumption. The amplifier is controlled by 6-bit correction DAC to set bandwidth required for a given recordings. The paper presents our former measurement results and describes encountered problems. The design of amplifier is provided with emphasis on its limits. Additionally, the simulation results are also given.
  • Keywords
    CMOS integrated circuits; amplifiers; digital-analogue conversion; integrated circuits; medical signal detection; CMOS process; DAC; amplifier design; biomedical signal recording; biomedical signals acquisition; multichannel integrated circuit; size 180 nm; size 55 mum; size 58 mum; voltage 1.8 V; Bandwidth; Current measurement; Cutoff frequency; Frequency control; Frequency measurement; Leakage currents; ASIC; amplifier; biomedical recordings; leakage currents; multichannel architecture;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mixed Design of Integrated Circuits & Systems (MIXDES), 2015 22nd International Conference
  • Conference_Location
    Torun
  • Print_ISBN
    978-8-3635-7806-0
  • Type

    conf

  • DOI
    10.1109/MIXDES.2015.7208534
  • Filename
    7208534