Title :
Study and implementation of the precise temperature control used in airborne gravimetry
Author :
Li, Jilian ; Zhang, Kaidong ; Zhang, Qi ; Xia, Lurui
Author_Institution :
Coll. of Mechatron. Eng. & Automatics, Nat. Univ. of Defense Technol., Changsha, China
Abstract :
Temperature was a main factor that influenced and restricted an improvement of quartzose flexible accelerometer´s performance. To assure measurement accuracy of the Strapdown Gravimeter for airborne Survey (SG-A01), a stable temperature environment which changes were less than ±0.02°C was needed for the specific force measure system which was composed of three orthogonal accelerometers. To meet the requirement mentioned above, a method that contained two-stage temperature control system was brought forward to assure precision of temperature control. A series of static test shown that the method can reach the precision preliminarily.
Keywords :
accelerometers; force measurement; geophysical techniques; gravity; temperature control; airborne gravimetry; airborne survey; force measure system; precise temperature control; quartzose flexible accelerometer; static test; strapdown gravimeter; Accelerometers; Educational institutions; Gravity measurement; Mechatronics; Silicon compounds; Temperature control; Temperature measurement; accelerometers; airborne gravimetry; precise temperature control;
Conference_Titel :
Intelligent Control and Automation (WCICA), 2010 8th World Congress on
Conference_Location :
Jinan
Print_ISBN :
978-1-4244-6712-9
DOI :
10.1109/WCICA.2010.5554410