DocumentCode :
1688449
Title :
Use of near-infrared spectroscopy in evaluating upper extremity muscle hemodynamics during an eight-hour exposure to repetitive hand-wrist motions
Author :
Maikala, R.V. ; Ciriello, V.M. ; Brien, N. V O ; Banks, J.J. ; Rivard, A.J.
Author_Institution :
Center for Phys. Ergonomics, Liberty Mutual Res. Inst. for Safety, Hopkinton, MA, USA
fYear :
2012
Firstpage :
508
Lastpage :
512
Abstract :
We evaluated local hemodynamic responses simultaneously from flexor and extensor muscles in the forearm of 14 male workers while performing repetitive ulnar deviation task for 8 hours. First, a psychophysical approach was utilized to identify participants´ maximum acceptable torque (in Nm) at 15 and 25 repetitions per min (rpm). Second, while performing an ulnar deviation task repetitively for 8 hours at their psychophysically acceptable torque, Tissue Oxygenation Index (TOI) and Tissue Hemoglobin Index (THI) were collected. Workers exerted lower acceptable torque for the task with a repetition rate of 25 rpm as compared to 15 rpm (3.57 ± 2.7 versus 3.97 ± 2.5 Nm, P=0.014). When the TOI responses (representing muscle oxygen saturation) after each hour of effort were matched for the net acceptable torque exerted, the mean TOI-torque ratio was 10.2% higher in the flexor region as compared to the extensor region throughout the workday. Also, when corrected for the torque exerted during both the 15 rpm and 25 rpm tasks, a dynamic adjustment of THI (representing muscle blood volume) to the time course of TOI resulted, suggesting a strong coupling between muscle blood flow and oxygen uptake as the task continued. Although the acceptable torque exerted was lowest for the 25 rpm task, the increased TOI-torque ratio coupled with increased THI per torque generated suggests that working at 25 rpm is metabolically more challenging than at 15 rpm.
Keywords :
biological tissues; blood; blood flow measurement; haemorheology; infrared spectra; infrared spectroscopy; molecular biophysics; muscle; oximetry; proteins; blood flow; extensor muscles; flexor muscles; maximum acceptable torque; muscle blood volume; muscle oxygen saturation; near-infrared spectroscopy; psychophysical approach; repetitive hand-wrist motions; repetitive ulnar deviation task; time 8 hr; tissue hemoglobin index; tissue oxygenation index; upper extremity muscle hemodynamics; Blood; Ergonomics; Hemodynamics; Indexes; Muscles; Torque; Wrist; Maximum Acceptable Torque; Near-infrared Spectroscopy; Ulnar Deviation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering (ICoBE), 2012 International Conference on
Conference_Location :
Penang
Print_ISBN :
978-1-4577-1990-5
Type :
conf
DOI :
10.1109/ICoBE.2012.6179070
Filename :
6179070
Link To Document :
بازگشت