DocumentCode :
1691755
Title :
An non-uniform sampling strategy for physiological signals component analysis
Author :
Molin Jia ; Chaoyang Wang ; Kui-Ting Chen ; Baba, Toshihiko
fYear :
2013
Firstpage :
526
Lastpage :
529
Abstract :
The conventional approach cannot meet the requirement of physiological signal analysis to extract the main component of the acquired signal. This paper proposes a non-uniform sampling strategy with corresponding fast Fourier transform (FFT) for signal component analysis. The simulation results of different approaches are analyzed and compared. The proposed strategy has the superior anti-aliasing performance than conventional approach with lower sampling rate.
Keywords :
fast Fourier transforms; medical signal processing; physiology; sampling methods; FFT; fast Fourier transform; nonuniform sampling strategy; physiological signals component analysis; superior anti-aliasing performance; Analytical models; Equations; Frequency response; Mathematical model; Medical services; Physiology; Signal analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Consumer Electronics (ICCE), 2013 IEEE International Conference on
Conference_Location :
Las Vegas, NV
ISSN :
2158-3994
Print_ISBN :
978-1-4673-1361-2
Type :
conf
DOI :
10.1109/ICCE.2013.6487006
Filename :
6487006