• DocumentCode
    1694347
  • Title

    Evaluation of power losses in a boost PFC unit by temperature measurements

  • Author

    Viswanathan, K. ; Oruganti, R.

  • Author_Institution
    Centre for Power Electron., Singapore Nat. Univ.
  • fYear
    2006
  • Abstract
    High power conversion efficiency is an important requirement of the front-end power-factor corrected (PFC) boost rectifier used in shaping the ac input current in a typical modern off-line power supply. A reasonably accurate estimate of the power losses in individual components is essential in order to improve the efficiency of the PFC rectifier. In this paper, difficulties in the measurement of individual component power losses with particular reference to an ac-dc converter are brought out. A method of loss evaluation by measurement of temperatures of individual components and surrounding ambient is presented. Experimental results carried out on the front-end boost PFC rectifier of a commercial ac-dc converter are presented to validate the loss estimation method
  • Keywords
    AC-DC power convertors; losses; power factor correction; rectifiers; ac-dc converter; boost PFC unit; loss estimation method; off-line power supply; power conversion efficiency; power factor corrected boost rectifier; power losses; temperature measurements; AC-DC power converters; Bandwidth; Loss measurement; MOSFET circuits; Measurement units; Oscilloscopes; Power measurement; Probes; Temperature measurement; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 2006. APEC '06. Twenty-First Annual IEEE
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-9547-6
  • Type

    conf

  • DOI
    10.1109/APEC.2006.1620546
  • Filename
    1620546