Title :
Estimate and evaluation of the control area PFR based on PMU
Author :
Zheng, Tao ; Dai, Zemei ; Gao, Fuying
Author_Institution :
NARI Technol. Dev. Co., Ltd., Nanjing, China
Abstract :
This paper proposes a method for online monitoring the primary frequency regulation performance of the control area in wide area measurement system (WAMS) based on the dynamic measurement data collected by synchronous phasor measurement unit (PMU). First, it discovers the variation through watching over the power grid frequency and the tie-lines power between control areas in real time. It measures the frequency static characteristic coefficients and calculates the expected invoking capacity of the primary frequency regulation of the control areas, compares with the actual invoking capacity through the analysis on the system frequency and the tie-lines exchange power data, combining with the power vacancy. It estimates the primary frequency regulation performance by the response index of the control area.
Keywords :
frequency control; phasor measurement; power control; power grids; power system control; WAMS; control area PFR estimation; control area PFR evaluation; dynamic measurement data collection; frequency static characteristic coefficient; online monitoring; power grid frequency; primary frequency regulation performance; response index; synchronous PMU; synchronous phasor measurement unit; tie-lines exchange power data; wide area measurement system; Automatic frequency control; Generators; Indexes; Power grids; Time frequency analysis; frequency bias coefficient; phasor measurement unit (PMU); primary frequency regulation (PFR); wide area measurement system (WAMS);
Conference_Titel :
Advanced Power System Automation and Protection (APAP), 2011 International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-9622-8
DOI :
10.1109/APAP.2011.6180479