Abstract :
Micro-springs are characterized and demonstrated in integrated circuit (IC) packaging and microelectromechanical system (MEMS) metrology applications. The springs are based on lithographically defined stress-engineered films and are compliant, electrically conducting and have micrometer scale dimensions. The force-displacement is experimentally measured and found to have constant stiffness through the majority of compression. Fretting experiments are performed to investigate the potential for intermittent electrical contact when the springs are used as a solder-less pressure contact for integrated circuit packaging. While operating at <1 mN of force, orders of magnitude lower than macroscopic connectors, no glitches slower than 4 nsec are observed for thousands of shake cycles. The springs are also demonstrated as scanning probes for non-destructive imaging of high-aspect ratio MEMS structures. Sidewall line-scans and tapping mode images in deep silicon trenches are presented using tip heights over ten times taller than commercial probes.
Keywords :
elastic constants; elemental semiconductors; integrated circuit packaging; micromechanical devices; scanning probe microscopy; silicon; wear; MEMS structures; Si; constant stiffness; electrical contact; fretting; integrated circuit packaging; microelectromechanical system; nondestructive imaging; scanning probe MEMS metrology; silicon trenches; springs; tapping mode images; Application specific integrated circuits; Conductive films; Contacts; Force measurement; Integrated circuit packaging; Metrology; Microelectromechanical systems; Micromechanical devices; Probes; Springs;
Conference_Titel :
TRANSDUCERS, Solid-State Sensors, Actuators and Microsystems, 12th International Conference on, 2003
Conference_Location :
Boston, MA, USA
Print_ISBN :
0-7803-7731-1
DOI :
10.1109/SENSOR.2003.1215340