Neutral grounding method and protection co-ordination on several direct-connected generators in parallel
Author :
Zhao LiangLiang ; Gao FengRong
Author_Institution :
China Aviation Planning & Constr. Dev. Co., Ltd., Beijing, China
Volume :
3
fYear :
2011
Firstpage :
1691
Lastpage :
1695
Abstract :
There is a power micro grid composed of several diesel generators, cables, step-down transformers and motors. The similar grid scheme is applied to airports, mining plant, and oil platforms etc. In the micro grid, the generating system needs to meet the demands not only for supplying stable electricity, but also for keeping the islanding operation. As we know, damages of generator stator insulation easily happen due to the generator arcing ground current beyond the limit. In this paper, naturally it is available that high resistance grounding is used at one of several direct-connected generators neutral in a micro grid, and to keep only one generator grounding at a time among them in parallel, there is one automatic isolator at each generator neutral by the generator control system. Further, the protection co-ordination basing on this grounding method that is reliable earth-fault protection scheme has been used to this micro grid. The neutral grounding method, the protection configuration of feeders, generators and buses, and partly the settings calculation of the relay device are introduced and analyzed in this paper, and the available complete scheme has been adopted.
Keywords :
diesel-electric generators; distributed power generation; earthing; electric motors; machine protection; power cables; power distribution faults; power distribution protection; power distribution reliability; power generation faults; power generation protection; power generation reliability; power transformers; relay protection; automatic isolator; diesel generator; direct-connected generator grounding; earth-fault protection scheme; feeder protection configuration; generating system; generator arcing ground current; generator control system; generator stator insulation damage; high resistance grounding method; islanding operation; neutral grounding method; power microgrid; protection coordination; relay device; step-down transformer; Generators; Relays; Neutral grounding; direct-connected generator; micro grid; protection;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Advanced Power System Automation and Protection (APAP), 2011 International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-9622-8
Type :
conf
DOI :
10.1109/APAP.2011.6180645
Filename :
6180645
Link To Document :
بازگشت