• DocumentCode
    1705349
  • Title

    The appropriate dimensions of the porous micro-channel for blood ions separation

  • Author

    Seddigh, M. ; Abolfathi, N.

  • Author_Institution
    Dept. of Med. Eng., Amirkabir Univ., Tehran, Iran
  • fYear
    2013
  • Firstpage
    17
  • Lastpage
    21
  • Abstract
    Separation of nano-particles from the fluid in micro-channels has a wide application in industry and is the subject of a plenty of researches today. In the present paper, the flow of blood plasma which contains ions and is considered as nano-particles in a micro-channel has been studied. The channel inside wall is of a porous material which consists of amino functionalized group-type one that causes the ions to separate from the blood and absorb to the channel wall because of electrostatic interaction between blood ions and micro-channel wall material. Based on this study at first time, an optimum dimensions have been represented to decrease the process time and channel length.
  • Keywords
    blood; flow through porous media; haemodynamics; microchannel flow; nanomedicine; nanoparticles; porous materials; two-phase flow; blood ion separation; blood plasma flow; channel length; electrostatic interaction; microchannel wall material; nanoparticles; porous material; porous microchannel; Absorption; Blood; Educational institutions; Equations; Fluids; Ions; Mathematical model; Blood ions; Micro-channel; Porous channel; Separation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering (ICBME), 2013 20th Iranian Conference on
  • Conference_Location
    Tehran
  • Type

    conf

  • DOI
    10.1109/ICBME.2013.6782185
  • Filename
    6782185