    Study of the efficacy of respiratory gating in myocardial SPECT using the new 4D NCAT phantom

  • Author

    Segars, W. Paul ; Tsui, Benjamin M W

  • Author_Institution
    Dept. of Biomed. Eng., North Carolina Univ., Chapel Hill, NC, USA
  • Volume
    3
  • fYear
    2001
  • Firstpage
    1536
  • Abstract
    Respiratory motion can cause artifacts in myocardial SPECT images, which can lead to the misdiagnosis of cardiac diseases. One method to correct for respiratory artifacts is through respiratory gating. We study the effectiveness of respiratory gating through a simulation study using the newly developed NURBS-based cardiac-torso (NCAT) phantom. The organ shapes in the NCAT phantom are formed using non-uniform rational b-splines (NURBS) and are based on detailed human image data. With its basis on actual human data, the NCAT phantom realistically simulates human anatomy and motions such as the cardiac and respiratory motions. With the NCAT software, we generated 128 phantoms over one respiratory cycle (5 seconds per cycle) with the diaphragm and heart set to move a total of 4 cm from end-inspiration to end-expiration. The heart was set to beat at a rate of 1 beat per second resulting in a total of five heart cycles. We divide the respiratory cycle into different numbers of respiratory gates (16, 8, and 4) by averaging the phantoms. For each gate, we generate its projection data using an analytical projection algorithm simulating the effects of attenuation, scatter, and detector response. We then reconstruct the projections using an iterative OS-EM algorithm compensating for the three effects. The reconstructed images for each gating method were examined for artifacts due to the respiratory motion during that gate. We found that respiratory artifacts are significantly reduced if the respiratory motion of the heart that occurs during a gating time period is 1 cm or less. We conclude that respiratory gating is an effective method for reducing effects due to respiration. The timing of the gates is dependent on the extent of the heart´s motion during respiration.
  • Keywords
    algorithm theory; biomechanics; cardiology; lung; medical image processing; single photon emission computed tomography; splines (mathematics); NCAT software; actual human data; analytical projection algorithm; attenuation; cardiac diseases; cardiac motions; detailed human image data; detector response; diaphragm; end-expiration; end-inspiration; four dimensional NCAT phantom; gating method; gating time period; heart´s motion; human anatomy; iterative OS-EM algorithm; misdiagnosis; myocardial single photon emission computed tomography images; nonuniform rational b-splines-based cardiac-torso phantom.; organ shapes; projection data; reconstructed images; respiratory artifacts; respiratory cycle; respiratory gating; respiratory motion; scatter; simulation; Cardiac disease; Heart; Humans; Image reconstruction; Imaging phantoms; Myocardium; Shape; Spline; Surface reconstruction; Surface topography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1008630
  • Filename
    1008630