• DocumentCode
    170605
  • Title

    Noninvasive cardiac output monitoring system based on photoplethysmography

  • Author

    Can Wang ; Chao Huang ; Shuming Ye

  • Author_Institution
    Key Lab. of Biomed. Eng. of Minist. of Educ., Zhejiang Univ., Hangzhou, China
  • fYear
    2014
  • fDate
    16-18 May 2014
  • Firstpage
    669
  • Lastpage
    673
  • Abstract
    Cardiac output (CO) is the key indicator of the state of cardiac function. To realize noninvasive, continuous, portable, reproducible cardiac output monitoring, we design a cardiac output monitoring system based on photoplethysmography(PPG) which is stable, non-invasive and convenient to collect. K-calibration algorithm is used in the software part of this system. The main idea of K-calibration algorithm is to calibrate the constant K value on the basis of the relationship between the stroke volume (SV) and PPG from invasive SV, then combine the K value and the noninvasive PPG to calculate the SV, and calculate CO from SV. We collect the invasive SV by FloTrac / Vigileo monitor, and at the same time collect the PPG signals and some other parameters, then combine the calibrated K value and PPG to calculate SV. After making a correlation analysis with the calculated SV and the invasive SV, the result shows that they have a good correlation with each other. Making a comparison between the continuous CO collected by our designed monitoring system in real time and the invasive CO collected by the FloTrac / Vigileo monitoring system will be our follow-up job. And the achievement can be used in mobile or wearable instrument.
  • Keywords
    calibration; correlation methods; electrocardiography; medical signal processing; patient monitoring; photoplethysmography; ECG; FloTrac monitoring system; K-calibration algorithm; PPG signal collection; Vigileo monitoring system; cardiac function state; constant K value calibration; correlation analysis; electrocardiogram; noninvasive cardiac output monitoring system; photoplethysmography; stroke volume; wearable instrument; Algorithm design and analysis; Biomedical monitoring; Correlation; Electrocardiography; Monitoring; Sensors; Software; K-calibration algorithm; PPG; cardiac output; noninvasive; software system;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Progress in Informatics and Computing (PIC), 2014 International Conference on
  • Conference_Location
    Shanghai
  • Print_ISBN
    978-1-4799-2033-4
  • Type

    conf

  • DOI
    10.1109/PIC.2014.6972419
  • Filename
    6972419