In this paper, the control performances of the three phase SVPWM inverter according to the phase current measuring method are compared. For this comparison, the current measuring methods using a current transducer (CT) and a shunt resistor are adopted. Furthermore, in the case of three shunt resistors are connected between under the emitter of power switch and the dc-link ground for phase current measuring in the SVPWM inverter, the restriction is analyzed and the output voltage compensation method is proposed to fix these problem. The experimental result using 1.5kW lab-prototype set is presented for the performance verification.
Keywords :
PWM invertors; electric current measurement; machine control; resistors; transducers; voltage control; DC-link ground; control performance; current transducer; output voltage compensation method; phase current measuring method; power 1.5 kW; power switch; shunt resistor; three phase SVPWM inverter; Current measurement; Inverters; Phase measurement; Resistors; Space vector pulse width modulation; Switches; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Vehicle Power and Propulsion Conference (VPPC), 2011 IEEE
Conference_Location :
Chicago, IL
ISSN :
Pending
Print_ISBN :
978-1-61284-248-6
Electronic_ISBN :
Pending
Type :
conf
DOI :
10.1109/VPPC.2011.6043084
Filename :
6043084
Link To Document :
بازگشت