DocumentCode :
170822
Title :
In situ thermal reliability testing methodology for novel thermal interface materials
Author :
Hantos, G. ; Juhasz, L. ; Rencz, M.
Author_Institution :
Budapest Univ. of Technol. & Econ., Budapest, Hungary
fYear :
2014
fDate :
24-26 Sept. 2014
Firstpage :
1
Lastpage :
5
Abstract :
A novel in situ reliability testing method and the prototype of an industrially applicable automated system (the Viking Reliability Tester) was described in this paper for the characterization of TIM aging effects in semiconductor devices. The introduced reliability testing hardware-software framework utilizes Mentor Graphics T3Ster thermal transient tester to analyze the stress-induced deviations in the heat flow path from the pre-stress reference results. Measurement results collected during the active or passive cycling of the DUTs at regular intervals serve as basis for the comparison. The details of the degradation process can be used as input for life-time prediction and for physics of failure modeling. The practical application of the concept was demonstrated on power LEDs, including details about pre-stress measurement results and aging test-plan.
Keywords :
ageing; failure analysis; light emitting diodes; semiconductor device reliability; semiconductor device testing; stress measurement; thermal engineering; DUT; Mentor Graphics T3Ster thermal transient tester; TIM aging effect; active cycling; failure modeling; hardware-software framework; heat flow path; in situ thermal reliability testing methodology; industrially applicable automated system; passive cycling; power LED; pre-stress measurement reference; semiconductor device; stress-induced deviation; thermal interface material; viking reliability tester; Aging; Heating; Light emitting diodes; Reliability; Semiconductor device measurement; Temperature measurement; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Thermal Investigations of ICs and Systems (THERMINIC), 2014 20th International Workshop on
Conference_Location :
London
Type :
conf
DOI :
10.1109/THERMINIC.2014.6972532
Filename :
6972532
Link To Document :
بازگشت