• DocumentCode
    1709756
  • Title

    Design of a wide-range non-contact temperature measurement and control system for a 2.45 GHz microwave furnace

  • Author

    Pert, E. ; Calame, J. ; Gershon, D. ; Carmel, Y. ; Lloyd, I. ; Wilson, O. ; Olorunyolemi, T.

  • Author_Institution
    Maryland Univ., College Park, MD, USA
  • fYear
    1999
  • Firstpage
    152
  • Abstract
    Summary form only given. The design of a pyrometric non-contact temperature measurement and control system for a 3 kW 2.45 GHz microwave processing furnace is presented. Design considerations specifically relevant to implementing non-contact temperature measurement and control over the wide range of 25 to 2500/spl deg/C are discussed. The completed system, in use as a research tool for microwave processing studies, provides versatile and contiguous control of sample heating from room temperature to the process temperature, with real-time access to parameters of the power control algorithm.
  • Keywords
    furnaces; microwave heating; power control; pyrometers; sintering; temperature measurement; 2.45 GHz; 25 to 2500 C; 3 kW; control system; design considerations; microwave processing furnace; microwave processing studies; power control algorithm; pyrometric noncontact temperature measurement; real-time access; Ceramics; Control systems; Educational institutions; Electromagnetic heating; Furnaces; Geometry; Plasma simulation; Plasma temperature; Temperature control; Temperature measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 1999. ICOPS '99. IEEE Conference Record - Abstracts. 1999 IEEE International Conference on
  • Conference_Location
    Monterey, CA, USA
  • ISSN
    0730-9244
  • Print_ISBN
    0-7803-5224-6
  • Type

    conf

  • DOI
    10.1109/PLASMA.1999.829396
  • Filename
    829396