DocumentCode
1710099
Title
Study on breakdown of magnet wire used in AC traction motor
Author
Tong, Laisheng ; Wu, Guangning ; Zhang, Guoqin ; Lin, Tongguang
Author_Institution
Sch. of Electr. Eng., Southwest Jiaotong Univ., China
Volume
1
fYear
2005
Firstpage
172
Abstract
AC traction motors are fed by fast switching inverters in express locomotive. Inter-turn insulation of AC traction motors is electrically more stressed than that in the conventional. In order to investigate the service life of AC traction motors, mechanism and characteristics of dielectric breakdown of magnet wire used in AC traction motors are studied in the paper. Experiments have been carried out on specimen according to the condition of AC traction motor. Aging factors of magnet wires under continuous pulses are introduced and influence of inorganic fillers on insulation aging is analyzed. Breakdown points are analyzed through energy spectrum analysis and electron microscopic photograph. Finally, the breakdown mechanism of magnet wire is explained by conducting micro-crack theory.
Keywords
ageing; electric breakdown; insulating materials; invertors; machine insulation; switching convertors; traction motors; AC traction motor; dielectric breakdown; electron microscopic photograph; energy spectrum analysis; express locomotive; inorganic fillers; insulation aging; interturn insulation; magnet wire traction; microcrack theory; switching inverters; Aging; Cable insulation; Dielectric breakdown; Dielectrics and electrical insulation; Electric breakdown; Electrons; Inverters; Magnetic analysis; Traction motors; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 2005. (ISEIM 2005). Proceedings of 2005 International Symposium on
Conference_Location
Kitakyushu
Print_ISBN
4-88686-063-X
Type
conf
DOI
10.1109/ISEIM.2005.193364
Filename
1496086