Abstract
Summary form only given. An overview of the neutron emission profiles measured in the Frascati Tokamak Upgrade (FTU) during the 1998 experimental campaign is presented. FTU is a high magnetic field compact device and takes part in the European tokamak project. The neutron emission profiles are obtained by means of a 6-channel collimator equipped with NE213 organic scintillators and neutron/gamma pulse shape discrimination circuitry. Particular care has been given to the construction of the multicollimator and it shielding components, due to the material.
Keywords
fusion reactor instrumentation; neutron detection; plasma diagnostics; scintillation counters; 6-channel collimator; European tokamak project; Frascati Tokamak Upgrade; NE213 organic scintillators; Tokamak neutron collimator diagnostic; compact device; neutron emission profiles; neutron/gamma pulse shape discrimination circuitry; shielding components; Building materials; Collimators; Magnetic field measurement; Magnetic shielding; Neutrons; Pulse circuits; Pulse shaping methods; Radioactive decay; Shape; Tokamaks;