DocumentCode
171169
Title
Bioabsorbable polymeric fracture fixation devices aim to reduce stress shielding in bone
Author
Becker, Gabriella ; Calvis, Allyn ; Hazlett, Lauren ; Verzi, Mary ; Paliwal, Manish
Author_Institution
Dept. of Biomed. Eng., Coll. of New Jersey, Ewing, NJ, USA
fYear
2014
fDate
25-27 April 2014
Firstpage
1
Lastpage
2
Abstract
Approximately 55,500 proximal humeral fractures require surgical fixation annually. The current standard for internal humeral fracture fixation involves implantation of metallic rigid fixation devices to prevent dislocation of bone fragments. However, rigid fixation devices have high stiffness characteristics which can cause stress shielding of bone. A second method of fixation, called biological fixation, reduces stress shielding by reducing stiffness with more flexible devices. However, this approach leads to increased incidences of delayed healing and nonunion of fracture fragments. The purpose of our design is to create a device that implements two bioabsorbable polymers that degrade at different rates in an attempt to provide rigid fixation during the initial fracture healing phase, followed by a period of biological fixation, allowing for functional healing and reduction of stress shielding over time. The bioabsorbable property of the design permits the device to remain in situ, thus eliminating the need for removal surgery and risk of surgical site infection. The design has been demonstrated to exhibit varying axial, torsional, and flexural stiffness over time. By combining the benefits of current devices, the proposed design provides an improved solution for proximal humeral fracture fixation.
Keywords
biodegradable materials; biomechanics; biomedical materials; bone; elastic constants; fracture; injuries; orthopaedics; polymers; prosthetics; stress effects; surgery; axial stiffness; bioabsorbable polymeric fracture fixation devices; bioabsorbable property; biological fixation; bone fragment dislocation; bone stress shielding; degradable polymer; delayed healing; flexible device; flexural stiffness; fracture fragment nonunion; functional healing; initial fracture healing phase; internal humeral fracture fixation; metallic rigid fixation device implantation; proximal humeral fracture fixation; removal surgery; rigid fixation devices; stiffness characteristics; stress shielding reduction; surgical fixation; surgical site infection risk; torsional stiffness; Bones; Degradation; Electronics packaging; Implants; Load modeling; Stress; Stress shielding; bioabsorbable polymers; fracture fixation; proximal humerus;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioengineering Conference (NEBEC), 2014 40th Annual Northeast
Conference_Location
Boston, MA
Type
conf
DOI
10.1109/NEBEC.2014.6972727
Filename
6972727
Link To Document