Wet flue gas desulfurization using a physical mixture of limestone and lime for energy savings
Author :
Zhao, Yi ; Guo, Tianxiang ; Zhang, Zili ; Xue, Fangming
Author_Institution :
Sch. of Environ. Sci. & Eng., North China Electr. Power Univ., Baoding, China
Volume :
3
fYear :
2011
Firstpage :
1826
Lastpage :
1829
Abstract :
Physical mixture of limestone and lime SOx absorbent was used to remove SO2 in wet flue gas desulfurization system (WFGD) in this paper. The effects of varied running parameters such as slurry pH, molar ratio of CaO to (CaO and CaCO3) and L/G ratio on removal efficiencies of SO2 were investigated experimentally. The rational operation conditions were obtained, in which slurry pH was 6.0, molar ratio of CaO to (CaO and CaCO3) was 0.25 and L/G ratio was 10L·m-3. Taking the selected power plant as an example, system energy savings could be achieved by using the physical mixture of limestone and lime SOx absorbent and the better economic benefit was obtained.
Keywords :
absorption; air pollution; atmospheric composition; flue gas desulphurisation; rocks; slurries; sulphur compounds; CaO molar ratio; SO2; energy saving system; lime SOx absorbent; lime physical mixture; limestone physical mixture; rational operation conditions; running parameter effect; slurry pH analysis; wet flue gas desulfurization system; Poles and towers; SOx absorbent; energy savings; lime; limestone; wet flue gas desulfurization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Water Resource and Environmental Protection (ISWREP), 2011 International Symposium on
Conference_Location :
Xi´an
Print_ISBN :
978-1-61284-339-1
Type :
conf
DOI :
10.1109/ISWREP.2011.5893606
Filename :
5893606