DocumentCode :
1716324
Title :
Interleaved Active Front-Ends Design Criteria for Reliability improvements
Author :
Triggianese, M. ; Liccardo, F. ; Marino, P.
Author_Institution :
Dipt. d´´Ing. del´´Inf., Seconda Univ. di Napoli, Aversa
fYear :
2007
Firstpage :
1220
Lastpage :
1225
Abstract :
This paper describes the advantages that can be obtained in ac/dc conversion, when an innovative four-quadrant converter, named synchronous active front-end (SAFE), is employed. The modular system, which increases the availability of the power delivering, can also be designed in order to obtain an improvement of the mission reliability. The reliability of single-AFE topology and the one of a SAFE are here compared. Based on the classical reliability prediction method, this contribution gives a design criteria of the optimum number of the parallel-connected converters and of their switching frequency, in order to match the reliability constrains.
Keywords :
AC-DC power convertors; reliability; switching convertors; ac-dc conversion; four-quadrant converter; interleaved active front-ends design criteria; parallel-connected converters; reliability constrains; reliability prediction method; switching frequency; synchronous active front-end; Availability; Power quality; Power system reliability; Prediction methods; Pulse width modulation; Pulse width modulation converters; Switching converters; Switching frequency; Topology; Voltage; Power quality; Pulse width modulating power converters; Reliability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Tech, 2007 IEEE Lausanne
Conference_Location :
Lausanne
Print_ISBN :
978-1-4244-2189-3
Electronic_ISBN :
978-1-4244-2190-9
Type :
conf
DOI :
10.1109/PCT.2007.4538490
Filename :
4538490
Link To Document :
بازگشت