DocumentCode :
1716528
Title :
Hydrogen detection using surface plasmon resonance in palladium films
Author :
Cavalcanti, Gustavo Oliveira ; Fontana, Eduardo ; Oliveira, Sérgio Campello
Author_Institution :
Dep. de Eletron. e Sist., Univ. Fed. de Pernambuco (UFPE), Recife, Brazil
fYear :
2009
Firstpage :
312
Lastpage :
315
Abstract :
We investigate the performance of Pd films for the development of H2 sensors based on the surface plasmon resonance (SPR) effect. Experimental measurements were carried out on glass substrates sputtered with Pd thin films, using a homemade automatic reflectometer based on Kretschmann´s prism coupling configuration. The sensitivity for H2 detection measured experimentally was approximately 60% lower than that expected from calculations based on the optical constants tabulated in the literature, but exhibited the approximate trend in thickness dependency predicted theoretically. In spite of this difference, these results yield important findings for the design of SPR-based H2 sensors with maximum sensitivity.
Keywords :
gas sensors; palladium; surface plasmon resonance; Kretschmann prism coupling configuration; homemade automatic reflectometer; hydrogen detection; palladium films; surface plasmon resonance; thin films; Glass; Hydrogen; Optical films; Optical sensors; Optical surface waves; Palladium; Plasmons; Reflectivity; Resonance; Substrates; SPR; component; hydrogen sensor; palladium films; reflectometer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave and Optoelectronics Conference (IMOC), 2009 SBMO/IEEE MTT-S International
Conference_Location :
Belem
ISSN :
1679-4389
Print_ISBN :
978-1-4244-5356-6
Electronic_ISBN :
1679-4389
Type :
conf
DOI :
10.1109/IMOC.2009.5427576