    Expanding the versatility of a more accurate accelerated Monte Carlo simulation for 3D PET: data correction of PET emission scans using 124I

  • Author

    Holdsworth, C.H. ; Dahlbom, M. ; Liu, A. ; Williams, L. ; Levin, C.S. ; Janecek, M. ; Hoffman, E.J.

  • Author_Institution
    Sch. of Med., California Univ., Los Angeles, CA, USA
  • Volume
    4
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    2105
  • Lastpage
    2109
  • Abstract
    Our Monte Carlo PET simulation for a 3D PET scan is able to simulate ~5 million coincidence events per minute per minute on 300MHz Sun dual processor workstation. This Is over two orders of magnitude faster than most other available Monte Carlo simulations for 3D PET and is fast enough to be employed as a scatter correction for 3D PET imaging. We have improved the accuracy of our simulation of a clinical ECAT HR+ scanner by analyzing the effect of the energy response of the detectors on simulated sinograms. We created a modified version of our simulation for 3D PET scans using 124I. Our initial version was five times slower than our simulation for FDG scans. We analyzed the distribution of the simulated detected coincidence events involving gamma rays and proposed an analytical method that corrected for these events. We found that this correction is subject to errors that can be exacerbated when used in conjunction with an analytical scatter correction that scales to the measured sinogram´s scatter tail. To reduce error, we have developed a faster, more detailed simulation for 124I. We are currently investigating the possibly of a fully Monte Carlo correction for both scatter and gamma ray coincidences in the future
  • Keywords
    Monte Carlo methods; iodine; medical image processing; positron emission tomography; 3D PET scan; 124I; I2; Monte Carlo PET simulation; clinical ECAT HR+ scanner; coincidence events; fully Monte Carlo correction; gamma ray coincidences; scatter correction; Acceleration; Analytical models; Detectors; Discrete event simulation; Error correction; Monte Carlo methods; Positron emission tomography; Scattering; Sun; Workstations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1009239
  • Filename
    1009239