Title :
Measurement of separating flow structures using a multiple-camera DPIV system
Author :
Humphreys, William M., Jr. ; Bartram, Scott M.
Author_Institution :
NASA Langley Res. Center, Hampton, VA, USA
fDate :
8/1/2001 12:00:00 AM
Abstract :
A novel multiple-camera system for the recording of digital particle image velocimetry (DPIV) images acquired in a two-dimensional separating/reattaching flow is described. The measurements were performed in the NASA Langley Subsonic Basic Research Tunnel as part of an overall series of experiments involving the simultaneous acquisition of dynamic surface pressures and off-body velocities. The DPIV system utilized two frequency-doubled Nd:YAG lasers to generate two coplanar, orthogonally-polarized light sheets directed upstream along the horizontal centerline of the test model. A recording system containing two pairs of matched high resolution, 8-bit cameras was used to separate and capture images of illuminated tracer particles embedded in the flow field. Background image subtraction was used to reduce undesirable flare light emanating from the surface of the model, and custom pixel alignment algorithms were employed to provide accurate registration among the various cameras. Spatial cross correlation analysis with median filter validation was used to determine the instantaneous velocity structure in the separating/reattaching flow region illuminated by the laser light sheets. In operation the DPIV system exhibited a good ability to resolve largescale separated flow structures with acceptable accuracy over the extended field of view of the cameras. The recording system design provided., enhanced performance versus traditional DPIV systems by allowing a variety of standard and non-standard cameras to be easily incorporated into the system
Keywords :
CCD image sensors; flow separation; flow visualisation; image registration; laser velocimetry; accurate registration; background image subtraction; custom pixel alignment algorithms; digital particle image velocimetry; dynamic surface pressures; frequency-doubled Nd:YAG lasers; illuminated tracer particles; incompressible flow; laser pulse separation; multiple-camera system; off-body velocities; orthogonally-polarized light sheets; simultaneous acquisition; spatial cross correlation analysis; synchronization timing system; two-dimensional separating/reattaching flow; Cameras; Digital recording; Fluid flow measurement; Frequency; Image resolution; Laser modes; NASA; Performance evaluation; System testing; Velocity measurement;
Conference_Titel :
Instrumentation in Aerospace Simulation Facilities, 2001. 19th International Congress on ICIASF 2001
Conference_Location :
Cleveland, OH
Print_ISBN :
0-7803-7022-8
DOI :
10.1109/ICIASF.2001.960238