DocumentCode :
1719658
Title :
Study of 5 and 10 mm thick CZT strip detectors
Author :
Macri, J.R. ; Dufour, P. ; Hame, L.A. ; Julien, M. ; McConnell, M.L. ; McClish, M. ; Ryan, J.M. ; Widholm, M.
Author_Institution :
Space Sci. Center, New Hampshire Univ., Durham, NH, USA
Volume :
4
fYear :
2001
fDate :
6/23/1905 12:00:00 AM
Firstpage :
2316
Lastpage :
2320
Abstract :
We report progress in the study of 5 and 10 mm thick CdZnTe strip detectors featuring orthogonal coplanar anode contacts. This novel anode geometry combines the advantages of pixel detectors with those of double-sided strip detectors. Like pixel detectors. these are electron-only devices that perform well as hard X-ray and γ-ray spectrometers and imagers even in the thicker configurations required for reasonable detection efficiency at 1 MeV. Like double-sided strip detectors in an N×N configuration, these detectors require only 2N readout channels to form N2 "pixels". Unlike double-sided strip detectors, all signal contacts for spectroscopy and 3-d imaging are formed on one detector surface. Polymer flip chip bonding to a ceramic substrate is employed resulting in a rugged and compact detector assembly. Prototype detector modules 5 mm thick have been fabricated and tested. Prototype modules, 10 mm thick, are currently in procurement. Measurements confirm these devices are efficient detectors throughout their volume. Sub-millimeter position resolution and energy resolution (FWHM) better than 3% at 662 keV and 15% at 60 keV throughout the detector volume are demonstrated. Options for processing the signals from the non-collecting anode strip contacts are discussed. Results from tests of one prototype circuit are presented. We also report on detector simulation studies aimed at defining an optimum geometry for the anode contacts and at determining optimum operating conditions and the requirements of the signal processing electronics
Keywords :
X-ray spectrometers; gamma-ray spectrometers; nuclear electronics; position sensitive particle detectors; semiconductor counters; signal processing; γ-ray spectrometer; 10 mm; 5 mm; 60 keV; 662 keV; CdZnTe; CdZnTe strip detectors; X-ray spectrometer; anode contacts; energy resolution; orthogonal coplanar anode contacts; polymer flip chip bonding; position resolution; signal processing electronics; Anodes; Energy resolution; Gamma ray detection; Gamma ray detectors; Geometry; Prototypes; Spectroscopy; Strips; X-ray detection; X-ray detectors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2001 IEEE
Conference_Location :
San Diego, CA
ISSN :
1082-3654
Print_ISBN :
0-7803-7324-3
Type :
conf
DOI :
10.1109/NSSMIC.2001.1009286
Filename :
1009286