Analysis of the sheath voltage in High-speed railway feeder cable grounding in single-ended mode
Author
Zhixing Yi ; Xiaobin Cao ; Guangning Wu ; Fangfang He ; Xianyi Zhang
Author_Institution
Sch. of Electr. Eng., Southwest Jiaotong Univ., Chengdu, China
fYear
2014
fDate
11-18 Oct. 2014
Firstpage
651
Lastpage
654
Abstract
With the scale construction of passenger dedicated line, in order to improve the reliability of traction power supply, 27.5 kV single core line cable is widely used in the power contact line of outlet and catenary power supply line. The high reliability of traction power supply system directly affects the overall reliability. When AC current flows through the conductor in cable, the shielding layer will generate a corresponding induced electromotive force of which the magnitude is mainly proportional to length of the cable and value of the current in the conductor. When value of induced electromotive force on the sheath is too large, it may cause the grounding fault of the cable and endanger the safety of the people and the equipment. In this paper, the simulation software PSCAD/EMTDC is used to build the model of the High-speed Railway All-parallel AT Traction Power Supply System. The feeder cable sheath one end direct grounding, the other end through the Cable sheath protector grounding, which is called Cable sheath single-grounded way; The feeder cable sheath middle direct grounding-two ends protector grounding, which is called Cable sheath midpoint-grounded way. Using PSCAD/EMTDC simulation software to measure the voltage of cable sheath under different length of cable, graph of voltage in cable sheath is obtained. Analyzing the voltage of cable sheath and graphic, applicable distance of the cable sheath single-grounded way and Cable sheath midpoint-grounded way are obtained. The result provides reference for the engineering.
Keywords
cable sheathing; earthing; power cables; railway engineering; traction power supplies; PSCAD-EMTDC; cable sheath midpoint-grounded way; cable sheath protector grounding; cable sheath single-grounded way; catenary power supply line; feeder cable sheath; grounding fault; high-speed railway all-parallel AT traction power supply system; induced electromotive force; passenger dedicated line; power contact line; shielding layer; single core line cable; two ends protector grounding; Cable insulation; Cable shielding; EMTDC; Grounding; PSCAD; Reliability engineering; Cable grounding way; PSCAD/EMTDC; The induced voltage on the cable sheath;
fLanguage
English
Publisher
ieee
Conference_Titel
Lightning Protection (ICLP), 2014 International Conference o
Conference_Location
Shanghai
Type
conf
DOI
10.1109/ICLP.2014.6973204
Filename
6973204
Link To Document