Title :
Improvement of thermal response in temperature controlled precise three-axis accelerometer with stabilized characteristics over a wide temperature range
Author :
Lee, Kyung Il ; Takao, Hidekuni ; Sawada, Kazuaki ; Don Seo, Hee ; Ishida, Makoto
Author_Institution :
Dept. of Electr. & Electron. Eng., Toyohashi Univ. of Technol., Japan
Abstract :
Improvement of the thermal response time of a temperature controlled three-axis accelerometer for high temperature environments with integrated microheaters and temperature sensors is presented. A detailed analysis of thermal response is carried out, and variation of thermal response with supply power is investigated using a simplified finite element method (FEM) model based on thermal response analysis. The thermal response analysis of the devices is investigated with the FEM program, ANSYS and infrared thermal measurement systems. The availability to application fields from the viewpoint of a short thermal response time is discussed. The time for a three-axis high temperature accelerometer to reach 300°C, with integrated micro-heaters and temperature sensors to reduce thermal drift characteristics, was analyzed as the thermal response time of the device. The simulated thermal response time (time until SOI piezoresistors actually become 300°C) of the three-axis high temperature accelerometer (using ANSYS) is about 600 ms, and the result measured by infrared temperature measurement systems is about 640 ms. Thermal measurement experimental results agreed well with these theoretical results. If electric power of about 260 mW is supplied to the integrated micro-heaters at around room temperature, the three-axis accelerometer reaches 300°C within 90 ms.
Keywords :
accelerometers; finite element analysis; microsensors; piezoresistive devices; silicon-on-insulator; temperature; temperature control; temperature sensors; thermal analysis; 300 C; FEM; MEMS; SOI piezoresistors; finite element method; high temperature accelerometer; integrated microheaters; integrated temperature sensors; precise three-axis accelerometer; silicon micromachined sensors; temperature controlled accelerometer; thermal drift characteristics; thermal response; thermal response analysis; thermal response time; Accelerometers; Delay; Finite element methods; Power supplies; Power system modeling; Temperature control; Temperature distribution; Temperature measurement; Temperature sensors; Time factors;
Conference_Titel :
Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05. The 13th International Conference on
Print_ISBN :
0-7803-8994-8
DOI :
10.1109/SENSOR.2005.1496538