Title :
Effect of FFT based algorithms on estimation of myoelectric signal spectral parameters
Author :
Merletti, R. ; Balestra, Gabriella ; Knaflitz, M.
Author_Institution :
Dipartimento di Elettronica, Politecnico di Torino, Italy
Abstract :
The effects of epoch duration, time windowing, and an algorithm upon the estimates of spectral parameters of surface myoelectric signals are discussed. Simulation with computer-generated signals shows that: (a) rectangular window and linear interpolation between contiguous spectral values are acceptable for epoch durations as short as 0.25 s; (b) for the raw periodogram and epoch durations of 1-2 s, coefficients of variation near 3-4% for fmean and 4-6% for f med should be expected; and (c) for epochs of 0.25 s these values double, and for shorter epochs the estimates become meaningless because of high variance. These conclusions should be taken into account when selecting windows and epoch durations for myoelectric signal analysis
Keywords :
bioelectric potentials; fast Fourier transforms; parameter estimation; spectral analysis; 0.25 s; 1 to 2 s; FFT based algorithms; coefficient of variation; computer-generated signals; epoch duration; linear interpolation; myoelectric signal spectral parameters; raw periodogram; rectangular window; time windowing; Computational modeling; Convolution; Electronics packaging; Frequency; Interpolation; Neuromuscular; Parameter estimation; Samarium; Sampling methods; Signal resolution;
Conference_Titel :
Engineering in Medicine and Biology Society, 1989. Images of the Twenty-First Century., Proceedings of the Annual International Conference of the IEEE Engineering in
Conference_Location :
Seattle, WA
DOI :
10.1109/IEMBS.1989.96066