DocumentCode
1727902
Title
Turn to turn insulation ageing diagnosis using frequency response analysis
Author
Tarifa, J. M Martinez ; Feito, J. Sanz ; Duarte, H. Amaris
Author_Institution
Dept. of Electr. Eng., Univ. Carlos III de Madrid, Espana, Spain
Volume
2
fYear
2004
Firstpage
880
Abstract
Inverter-fed induction motor applications are very common in many industrial processes. This provides electrical stresses higher than expected when feeding with power frequency. As a consequence, partial discharge activity appears. It has been reported that turn to turn insulation has become the weakest point within an inverter fed motor stator winding, so its ageing condition seems to be an important issue to be studied. This paper presents some promising results in turn to turn insulation ageing diagnosis after applying different electrical stresses by means of dielectric spectroscopy.
Keywords
ageing; copper; induction motors; insulated wires; insulation testing; invertors; partial discharges; stators; stress effects; Cu; dielectric spectroscopy; electrical stresses; frequency response analysis; industrial processes; inverter fed induction motor applications; inverter fed motor stator winding; partial discharge; power frequency; turn-turn insulation ageing diagnosis; Aging; Breakdown voltage; Dielectrics and electrical insulation; Frequency response; Impedance; Induction motors; Partial discharges; Pulse width modulation; Pulse width modulation inverters; Stress;
fLanguage
English
Publisher
ieee
Conference_Titel
Solid Dielectrics, 2004. ICSD 2004. Proceedings of the 2004 IEEE International Conference on
Print_ISBN
0-7803-8348-6
Type
conf
DOI
10.1109/ICSD.2004.1350572
Filename
1350572