• DocumentCode
    1728131
  • Title

    The CDF-II time-of-flight detector system

  • Author

    Cabrera, S. ; Fernandez, J. ; Gomez, Gerardo ; Piedra, Juan ; Rodrigo, T. ; Ruiz, Alberto ; Vila, I. ; Vilar, Ruth ; Grozis, C. ; Kephart, R. ; Stanek, R. ; Kim, D.H. ; Kim, Myung Su ; Oh, Yisok ; Kim, Young Keun ; Veramendi, G. ; Anikeev, K. ; Bauer, G.

  • Author_Institution
    Instituto de Fisica, Cantabria, Spain
  • Volume
    2
  • fYear
    2001
  • Firstpage
    927
  • Abstract
    A Time-of-Flight detector (TOF) has been added to the CDF-II experiment to provide charged kaon identification primarily for neutral B meson flavor determination. With its expected 100 ps time-of-flight resolution, the TOF system will be able to provide at least two standard deviation separation between K± and π± for momenta p < 1.6 GeV/c, complementing the specific ionization energy loss, dE/dx, measured in the new drift chamber. This paper describes the TOF detector and reports on the initial performance based on the data collected by the CDF-II so far.
  • Keywords
    nuclear electronics; solid scintillation detectors; CDF-II time-of-flight detector system; charged kaon identification; drift chamber; neutral B meson flavor determination; specific ionization energy loss; time-of-flight resolution; Detectors; Energy loss; Energy measurement; Energy resolution; Ionization; Laboratories; Loss measurement; Measurement standards; Mesons; Photomultipliers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1009707
  • Filename
    1009707