Development of a daily quality check procedure for the high resolution research tomograph (HRRT) using natural LSO background radioactivity
Author :
Knoess, Christof ; Gremillion, Tim ; Schmand, Matthias ; Casey, Mike E. ; Eriksson, Lars ; Lenox, Mark ; Treffert, Jon T. ; Vollmar, Stefan ; Fluegge, Guenter ; Wienhard, Klaus ; Heiss, W.-D. ; Nutt, Ron
Author_Institution :
Max-Planck Inst. for Neurological Res., Cologne, Germany
Volume :
2
fYear :
2001
Firstpage :
1115
Abstract :
A daily quality check (DQC) plays an important role for clinical medical systems like a Positron Emission Tomograph (PET). To guarantee image quality a constant monitoring of the scanner integrity is essential. On present PET scanners the built-in transmission sources are being used for the measurement of a uniform blank scan and the computation of detector-block efficiencies. These efficiencies can be compared to reference data and deviations indicate changes of the scanner condition. On the High Resolution Research Tomograph (ECAT HRRT) the design of the transmission source makes this method impractical. For that reason we investigated the use of the natural background radioactivity from the new scintillator material LSO as a uniform source. A procedure was developed to measure detector-block sensitivities and energy spectra directly. An initial quality check (QC) scan is the basis for comparison of daily scans, so that PMT gain shifts and specific hardware defects can be detected. In early stage of development of the DQC, the low LSO count rate results in long acquisition times. In the meantime, the listmode based data acquisition was changed so that it was possible to reduce the acquisition time to around 3 hours. With that this routine is now as practical as previous procedures in clinical routine.
Keywords :
lutetium compounds; positron emission tomography; quality control; solid scintillation detectors; High Resolution Research Tomograph; Lu2SiO5; PET; built-in transmission sources; clinical medical systems; clinical routine; daily quality check; detector-block efficiencies; image quality; listmode based data acquisition; natural LSO background radioactivity; positron emission tomograph; scanner integrity; scintillator material; transmission source; uniform blank scan; Biomedical imaging; Biomedical monitoring; Data acquisition; Energy measurement; Energy resolution; Hardware; Image quality; Positron emission tomography; Radioactive decay; Radioactive materials;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2001 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-7324-3
Type :
conf
DOI :
10.1109/NSSMIC.2001.1009746
Filename :
1009746
Link To Document :
بازگشت