• DocumentCode
    1729076
  • Title

    Experimental setup for very high resolution animal PET based on solid state detector

  • Author

    Park, S. ; Han, L. ; Wilderman, S.J. ; Sukovic, P. ; Czermak, A. ; Jalocha, P. ; Sowicki, B. ; Kowal, M. ; Dulinski, W. ; Maehlum, G. ; Nygard, E. ; Yoshioka, K. ; Fuster, J. ; Lacasta, C. ; Mikuz, M. ; Roe, S. ; Weilharnmer, J. ; Meier, D. ; Rogers, W.L.

  • Author_Institution
    Coll. of Eng., Michigan Univ., Ann Arbor, MI, USA
  • Volume
    2
  • fYear
    2001
  • Firstpage
    1120
  • Abstract
    A very high resolution animal PET instrument was investigated using Monte Carlo simulations. The instrument consists of an outer cylindrical BGO scintillation detector surrounding an inner cylindrical solid state detector composed of 0.3 mm square silicon pads. The interaction point of gamma rays that scatter in the pad detector can be accurately localized in 3D to within the pad volume. Total energy is known from the summed energy in silicon and BGO detectors. Simulation results show 192 μm spatial resolution for events in which both annihilation photons scatter in silicon detectors. We have constructed a prototype Compton PET instrument using two silicon detectors with 1.4 mm square pads, two CCDAQ data acquisition units that have digital signal processors, a source turntable, and a coincidence unit. Using this experimental setup the energy spectrum of photons from technetium (Tc-99m) was acquired with 2.45 keV energy resolution and the timing spectrum of annihilation photons from fluorine (F-18) was obtained with 1.9 ns timing resolution. This experimental, setup will be used to verify the simulation results for the high resolution PET that is expected to have a maximum resolution of 0.7 mm FWHM at the center of the field of view.
  • Keywords
    Monte Carlo methods; data acquisition; positron emission tomography; silicon radiation detectors; solid scintillation detectors; Be2GeO5; CCDAQ data acquisition units; Monte Carlo simulations; Si; annihilation photons; coincidence unit; digital signal processors; gamma rays; inner cylindrical solid state detector; interaction point; outer cylindrical BGO scintillation detector; prototype Compton PET instrument; silicon pads; solid state detector; source turntable; very high resolution animal PET; Animals; Electromagnetic scattering; Energy resolution; Instruments; Particle scattering; Positron emission tomography; Silicon; Solid scintillation detectors; Solid state circuits; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2001 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-7324-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2001.1009747
  • Filename
    1009747